Automated Threat Modeling

Brief Summary: FortiMail SQL Injection in Admin GUI (CVE-2025-53681)

A short review of CVE-2025-53681, an authenticated SQL injection vulnerability in the FortiMail administrative GUI. It lets a privileged attacker execute unauthorized code or commands, and it affects multiple FortiMail branches.

CVE Analysis

5 min read

ZeroPath CVE Analysis
ZeroPath CVE Analysis

2026-05-12

Brief Summary: FortiMail SQL Injection in Admin GUI (CVE-2025-53681)
Experimental AI-Generated Content

This CVE analysis is an experimental publication that is completely AI-generated. The content may contain errors or inaccuracies and is subject to change as more information becomes available. We are continuously refining our process.

If you have feedback, questions, or notice any errors, please reach out to us.

[email protected]

Introduction

An authenticated SQL injection vulnerability in the Fortinet FortiMail administrative GUI lets privileged users execute unauthorized code or commands, which could compromise the underlying email gateway system. For organizations that rely on FortiMail as their secure email gateway, the flaw is a meaningful risk if administrative credentials are compromised or if the threat model includes insiders.

FortiMail is Fortinet's enterprise secure email gateway product. Organizations deploy it widely to filter and protect against email-borne threats, including phishing, malware, and spam. Fortinet is a cybersecurity market leader, with nearly 6 billion USD in annual revenue and recognition in multiple Gartner Magic Quadrants, so FortiMail installations are common in large enterprise and government environments.

Technical Information

CVE-2025-53681 is classified under CWE-89 (Improper Neutralization of Special Elements used in an SQL Command). Fortinet tracks it internally as Bug ID 1169607. The flaw is in the Graphical User Interface (GUI) component of the FortiMail administrative portal.

The admin GUI does not properly sanitize user-supplied input before it puts that input into SQL queries. When a privileged administrator sends a specifically crafted HTTP or HTTPS request to the vulnerable GUI endpoint, the injected SQL commands reach the backend database without adequate neutralization.

Preconditions for Exploitation

Exploitation requires all of these conditions:

  1. The attacker must have authenticated access to the FortiMail system.
  2. The attacker must possess privileged administrative credentials.
  3. The attacker must send specifically crafted HTTP or HTTPS requests to the vulnerable GUI endpoint.

Attack Flow

An attack would proceed like this:

  1. An attacker with valid administrative credentials authenticates to the FortiMail web interface.
  2. The attacker identifies the vulnerable GUI endpoint that accepts user input and passes it to a backend SQL query.
  3. The attacker crafts a malicious HTTP or HTTPS request that carries SQL injection payloads aimed at that endpoint.
  4. The injected SQL commands execute in the context of the backend database, which could let the attacker execute unauthorized code or commands on the underlying system.

Severity Considerations

The severity ratings disagree. Fortinet rates this vulnerability Medium, with a CVSS v3 score of 6.3, while the NVD assigns a CVSS score of 7.2. The gap likely reflects different assessments of the impact scope, given the authentication requirement. Because the attack requires authenticated administrative access, the exposure surface is narrower than it would be for an unauthenticated vulnerability. With compromised admin credentials, credential stuffing, or an insider threat, though, an attacker could use this vulnerability as a pivot point for deeper compromise of the system. Successful exploitation leads to unauthorized code or command execution, so organizations should treat it as a high-consequence risk.

Affected Systems and Versions

The following FortiMail versions are confirmed vulnerable:

Product BranchVulnerable VersionsFixed Version
FortiMail 7.67.6.0 through 7.6.37.6.4 or above
FortiMail 7.47.4.0 through 7.4.57.4.6 or above
FortiMail 7.27.2.0 through 7.2.87.2.9 or above

Administrators running any version in these ranges should plan to upgrade immediately. Fortinet recommends these steps around the firmware upgrade:

  1. Before upgrading, save a copy of the FortiMail configuration.
  2. Before upgrading, verify the firmware image checksums to confirm integrity.
  3. After the upgrade is complete, clear the browser cache so the web interface renders properly.

Vendor Security History

Fortinet has a dedicated Product Security Incident Response Team (PSIRT) that handles vulnerability disclosures and publishes advisories through the FortiGuard portal. For this vulnerability, Fortinet released coordinated patches for three concurrent product branches (7.6, 7.4, and 7.2), which shows an established and mature vulnerability management process. Jaguar Perlas of the Fortinet Burnaby InfoSec team discovered the vulnerability internally, a sign of proactive internal security auditing. Internal discovery typically means no public proof of concept exists at the time of disclosure, which gives defenders a head start on patching.

Still, Fortinet products have historically been high-value targets for advanced threat actors. SQL injection vulnerabilities in the administrative interfaces of network appliances have attracted attention from both opportunistic and state-sponsored groups once details become public. As of May 12, 2026, Fortinet reports that this vulnerability is not known to be exploited in the wild.

References

Detect & fix
what others miss

Works with
  • GitHub
  • GitLab
  • Bitbucket
  • Azure DevOps Services
  • Gerrit
  • CVS
  • Jira
  • Linear
  • Slack
  • Security Compass
Explore integrations
Security magnifying glass visualization